Rotameter, Glass Tube Rotameter, Flow Meter, Leve Indicators, Temprature Indicators, Level Switches, Process Control Equipment, Process Control Systems, Ori Flow Meters, Orifice Plate, Multi Point Scanner, Sensores, Reflex Level Guages, Pitot Tubes, Process Control Instruments, Flow Measuring Instruments, Level Measuring Instruments, Temperature Measuring Instruments, Purge Rotameter, Metal Tube Rotameter, Capacitance Type Level Indicator, Level Measurement, Tubular Level Indicator, Reflex Level Indicator, Magnetic Level Indicator, Float Type Level Indicator, Board Type Level Indicator, Float Type Level Switch, Magnetic  Float Switch, Displacer Type Level Switch, Conductivity Type Level Controller, Level Controller, Variable Area Flowmeter, Digital Temperature Indicator, Digital Temperature Controller, Digital Temperature Scanner, Data Logger, Sensors, Thermowells
 
Ori - Flow Meter
 

Ori - Flow Meter

Ori - Flow Meter

Ori - Flow Meter

The Ori - flow meter measures flow by inserting an orifice at part of the piping, generating differential pressure before and behind the orifice by means of the flow, and extracting this differential pressure by a suitable method. Differential pressure ( P1-P2) of main orifice and the flow Q have shown in equation given below. The flow is proportional to the square root of the differential pressure.

 





Q : Volumetric flow
C : Flow co-efficient
F  : Cross sectional area of orifice hole 
g  : Acceleration of gravity
P1-P2 : Differential pressure
Y : Specific weight of fluid

The generated differential pressure is sent to a manometer or other differential pressure gauge and a differential flow meter can be formed by attaching a flow scale to this gauge. However, since the flow indication is a square root scale reading is difficult. Moreover, incase of remote transmission it is inconvenient because the evolution operation is performed to obtain linear relation. 
Therefore if a by-pass pipe connecting the before and behind point of the main orifice is installed and the flow is branched to that pipe to overcome these disadvantage, that flow becomes proportional to the differential

 


Installation example when flower meter using orifice ring in horizontal piping


Ori - Flow Meter

   

Capacity guide maximum m3/h of water

   

 
Flow value indicates the maximum flow range which can be measured when water (sp. gravity : 1.0, Viscosity : 1 Cp) is the standard. 
However minimum flow value for diameter ratio m : 0.3